On-Site Oxygen Generators for EMS | Fill Your Own Cylinders | NOVAIR USA
On-Site Oxygen · EMS & First Response

Oxygen when You Need It Most,
where You Need It Most.

NOVAIR's MOGS (Mobile Oxygen Generating System) fills your D, E, M and H/K cylinders right at the station using ambient air and standard electricity. Trailer and container options put the same system directly at the scene of the emergency to save more lives.

✓Fill 33 to 160 D-sized cylinders a day, on your schedule
✓93% +/-3% oxygen at up to 2200 psi
✓USA-made, certified to ISO 9001:2015 and ISO 13485:2016 standards

Size your Oxygen System

Tell us your cylinder types and daily volume. We will size the system and run your cost.

Takes about 2 minutes · No obligation

The Supply Problem Behind Every Call

Your Response Time Should Not Depend on a Delivery Truck

The Crew

Cylinders go out on calls and don't always come back full. Crews shouldn't have to hunt for a full oxygen tank at shift change.

The Chief

Oxygen is a line item you should control. Rental fees, hazmat charges, and annual increases get added on to a budget that was set months ago.

Emergency Management

In a storm, mass casualty event, or regional surge, the vendor you work with is serving everyone else too. That is exactly when deliveries stop.

★★★★★

"The MOGS 100 Oxygen Generator has run almost flawlessly in our system. It is an extremely reliable unit and well worth the investment."

Lynn B., Chief Officer · Kootenai County EMS

From Waiting on Deliveries
to Filling Your Own Cylinders.

BEFORE: A standing order you do not control, cylinders that disappear between agencies, and a supply chain that gets thinner the moment a real emergency starts

AFTER: Crews fill their own cylinders at the station from ambient air and standard electricity, at an ecomically viable cost you can budget years out

Up to 80%
In savings on oxygen supply costs

Ready to Take Oxygen Off Your Delivery Schedule?

We'll size a system to your oxygen volume, your station, and your budget.

How It Works

Ambient Air In. Full Cylinders Out.

1

Air and Power In

The MOGS runs on the ambient air we breathe using single-phase power at your facility. No bulk storage, no vendor infrastructure on your property.

2

PSA Separation and Compression

Pressure Swing Adsorption separates air molecules to allow a direct output of oxygen, with constant gas quality monitoring.

3

Crews Fill on Site

H/K cylinders are filled directly or run to a cascade system. D cylinders fill in the blast containment drawer.

93% +/- 3%
Oxygen Concentration
Up to 2200 psi
Cylinder Filling Pressure
20 – 100 SCFH
Oxygen Flow Rate
Cylinders filled per day
Cylinder sizeMOGS-20MOGS-50MOGS-100
D-sized3380160
E-sized2050100
M-sized4918
H/K-sized2510
NOVAIR MOGS-20 mobile oxygen generating system with doors open

MOGS-20

★★★★★

“Very happy with the product and the experience!”

Richie S., Lexington County EMS
The Range

Sized for a Single Station or a Whole Region.

MOGS-20

20 SCFH · 9.44 LPM

MOGS-50

50 SCFH · 23.6 LPM

MOGS-100

100 SCFH · 47.2 LPM

MOGS in Trailers

O2 Wherever You Need

Not Sure Which Size Fits Your Needs?

Tell us how many cylinders you go through in a week and we'll do the math with you.

Proof, Not Promises

Hundreds of Locations Already Filling Their Own

First responders in the City of Selma fill D-sized cylinders daily in the blast containment chamber, two at a time, to about 2,200 psi. The two H/K-sized cylinders on the back connect to a cascade system, so Selma can supply emergency teams across the area.

On the stored pressure alone, a crew can fill 10 to 15 cylinders before the machine needs to rebuild, and it climbs back to 1,800 to 2,200 psi on its own while it sits.

Daniel Diaz, EMS Supervisor · City of Selma, California

EMS crew filling an oxygen cylinder at the station

"These machines have been phenomenal for us. They keep our ambulances going with little or no downtime. We love these machines and are very happy for the purchase."

Troy Gibbs, Chief · New Castle EMS, Indiana
NOVAIR MOGS oxygen generator installed at an EMS station

"In less than three years, we were able to save enough money to pay for the MOGS unit with the oxygen needs of our system. We [now] prevent the loss of cylinders to other agencies."

Lynn B., Chief Officer · Kootenai County EMS
Before You Ask

The Questions Chiefs Actually Ask

What oxygen equipment does NOVAIR offer for EMS agencies and fire departments?

NOVAIR manufactures the Mobile Oxygen Generating System (MOGS) line for first responders. These systems generate oxygen on-site and fill cylinders in-house, removing dependence on scheduled deliveries. MOGS units are available in three sizes and can be installed at a station or mounted in a custom NOVAIR trailer for deployment directly to an incident.

How much does an on-site oxygen cylinder refilling station cost for a fire department?

Cost varies by model and required oxygen flow rate. NOVAIR's Mobile Oxygen Generating System (MOGS) is available in three sizes to match different agency volumes. After the upfront equipment investment, ongoing costs are limited to routine maintenance and standard electricity. Speak with a US-based NOVAIR representative for a quote tailored to your call volume and cylinder needs.

What purity does the MOGS produce, and is that right for EMS use?

The MOGS produces 93% (+/-3%) oxygen with continuous quality monitoring, with automatic safety shutdown if needed. Our team will walk you through exactly what the equipment delivers to meet all requirements.

What types of cylinders can NOVAIR's EMS oxygen systems fill?

NOVAIR's MOGS systems can fill a range of cylinder sizes. Depending on the model, multiple D, E, M, H, or K-sized cylinders can be filled per day. A blast containment chamber can hold two D-sized cylinders, and H/K-sized cylinders can be mounted or connected to a cascade system.

Can the system be deployed to the emergency site instead of staying at the station?

Yes. MOGS systems can easily fit through a normal-sized doorway and can be placed in an average truck to be transported. A MOGS model can also be mounted in a specialized NOVAIR trailer with attached generator, allowing oxygen to be easily produced at a staging area, shelter, or field site.

What happens if it goes down during a surge?

NOVAIR provides direct manufacturer service and support, not a reseller relationship. Most agencies also keep a cylinder reserve or a cascade system during transition. We will help you with that redundancy during installation.

Disclaimer: These products are not FDA cleared for direct connection to a human healthcare facility oxygen delivery system or for human patient direct use in the USA. Product operators for human healthcare applications are wholly accountable for registration as a pharmaceutical manufacturer and for all necessary related quality and safety testing. NOVAIR may assist in set-up and operation of our equipment, but such assistance does not constitute a guarantee of safety and performance related to human medical use of the oxygen generated. For guidance, please visit https://www.fda.gov/media/70973/download.
Why NOVAIR?

Built for Work That Cannot Wait

American-Made, Certified

Manufactured in North Tonawanda, New York. NOVAIR USA is certified to ISO 9001:2015 and ISO 13485:2016 standards.

Safety Built Into the Machine

Emergency stop, automatic safety shutdown, constant purity monitoring, and a PLC controller in isolated electrical enclosures.

Direct Manufacturer Support

Design, installation, crew training and service come straight from NOVAIR. Hundreds of fire and EMS installations worldwide.

★★★★★

"It's pretty simple to use. Just like that, you've got your own oxygen tanks filled and ready to go."

Daniel Diaz, EMS Supervisor · City of Selma

What would filling your own cylinders save you?

Bring your current oxygen invoices and cylinder counts. We'll run the real numbers against a system sized for your agency.


Telephone: (866) 877-7660
Email Address: info@novair-usa.com
Website: novair-usa.com

NOVAIR USA Corporation
814 Wurlitzer Drive
North Tonawanda, NY 14120 USA

Copyright © 2026 NOVAIR USA Corp. All Rights Reserved